A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Demand-type gas supply system for rocket borne thin-window proportional counters


    Beteiligte:
    Acton, L. W. (Autor:in) / Caravalho, R. (Autor:in) / Catura, R. C. (Autor:in) / Joki, E. G. (Autor:in)


    Erscheinungsdatum :

    01.11.1977


    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch




    A ruggedized thin-window proportional-counter tube

    Schnopper, H. W. / Shields, R. A. | NTRS | 1967


    Lexan coating to eliminate the UV sensitivity of soft X-ray proportional counters with a polypropylene window

    Fabricant, D. G. / Goddard, R. E. / Harnden, F. R., Jr. et al. | NTRS | 1979


    A Ruggedized Thin-Window Proportional-Counter Tube

    H. W. Schnopper / R. A. Shields | NTIS | 1967


    The suppression of destructive sparks in parallel proportional counters

    Cockshott, R.A. / Mason, I.M. | Tema Archiv | 1984


    Rocket-borne cryogenic air samplers

    Denton, E. H. | NTRS | 1970