The results of testing the flight thrusters on the SERT II spacecraft during the 1974 test period are presented. The most notable result was the clearing of the high voltage short from thruster 2 and the successful stable operation of its ion beam. Test periods were limited to 70 minutes or less by earth eclipse of the spacecraft solar array and by ground station coverage limitations. Thruster 2 was restarted 26 times with an ion beam produced 21 times. The high voltage short remains in thruster 1, but the cathodes were restarted 12 times to demonstrate continued restart capability. The propellant feed systems, power processors, and spacecraft ancillary equipment were demonstrated to be functional after 4-1/2 years in space. In addition to the thruster tests, a neutralizer cathode was operated separately to demonstrate that the potential level of a spacecraft could be controlled by the neutralizer alone.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    SERT II thruster space restart - 1974


    Beteiligte:
    Kerslake, W. R. (Autor:in) / Finke, R. C. (Autor:in)

    Kongress:

    American Institute of Aeronautics and Astronautics, Electric Propulsion Conference ; 1975 ; New Orleans, LA


    Erscheinungsdatum :

    01.03.1975


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Sert 2 Thruster Space Restart, 1974

    W. R. Kerslake / R. C. Finke | NTIS | 1975


    SERT II thruster space restart - 1974

    KERSLAKE, W. / FINKE, R. | AIAA | 1975


    SERT 2 thruster space restart, 1974

    Kerslake, W. R. / Finke, R. C. | NTRS | 1975


    SERT 2 thruster restart - 1974

    Kerslake, W.R. / Finke, R.C. | Tema Archiv | 1975


    SERTII Spacecraft Thruster Restart, 1974

    William R. Kerslake / Robert C. Finke | AIAA | 1975