Tests were performed on 12 cooling patches of various designs to establish criteria for the evaluation of their performance in liquid-cooled suits in industrial, military and aerospace applications. The thermal effectiveness value was 0.088 for patch designs with a double spiral flow pattern, and 0.075 for patch designs with a parallel flow pattern. The ratio of thermal energy transfer rate to cooling-medium pumping power requirement is indicated as the prime performance characteristic to be considered in the selection and rating of cooling patches.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Comparative study of patches for liquid cooled garments.


    Beteiligte:
    Shitzer, A. (Autor:in) / Chambers, A. B. (Autor:in)


    Erscheinungsdatum :

    01.08.1973


    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Comparative study of patches for liquid cooled garments.

    SHITZER, A. / CHAMBERS, A. B. | AIAA | 1973



    Liquid cooled garments

    Midwest Research Institute, Kansas City, Mo. | TIBKAT | 1975



    Control Algorithms For Liquid-Cooled Garments

    Drew, B. / Harner, K. / Hodgson, E. et al. | NTRS | 1988