The electrical subsystem of the 2-to 15-kilowatt Brayton power conversion system was evaluated under various operating and off-design temperature conditions in a vacuum environment. Overall operation was satisfactory. Speed controller operation is a major cause of distortion in the system ac voltage and current waveforms. This distortion has a small, but potentially significant effect on the performance of individual subsystem components.