An analytical investigation is presented showing the effect of film cooling using single and double slots. The analysis considers the tangential injection of a gas of the same molecular weight as the main flow into a laminar boundary layer. Results in terms of heat transfer to the wall are presented for different slot heights, and injection velocities for both single and double slot configurations. The results indicate that the double slot is a more effective means of film cooling than the single slot.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Multiple slot laminar film cooling.


    Beteiligte:
    Sherman, A. (Autor:in) / Yeh, H. (Autor:in) / Reshotko, E. (Autor:in) / Mcassey, E., Jr. (Autor:in)

    Kongress:

    American Institute of Aeronautics and Astronautics, Thermophysics Conference ; 1972 ; San Antonio, TX


    Erscheinungsdatum :

    01.04.1972


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Multiple Slot Laminar Film Cooling

    AUTHUR SHERMAN / HSUAN YEH / ELI RESHOTKO AND EDWARD MCASSEY | AIAA | 1973


    Multiple slot laminar film cooling

    SHERMAN, A. / YEH, H. / RESHOTKO, E. et al. | AIAA | 1972



    Film Cooling by Oblique Slot Injection