The Defense Special Weapons Agency (DSWA) and the Navy are funding a project concept to provide information about an airframe, which includes a rocket motor, to help them meet program range and lethality requirements. The airframe is based on the Army high capacity artillery projectile (HICAP) concept, and the rocket motor is being developed. As a part of a static burn test of the rocket motor, the chamber pressure was monitored to aid in performance evaluation. It is also desirable to obtain the same chamber pressure information during the early flight tests of the projectile. Thus, it was decided to telemeter the on-board pressure data to provide information about the rocket motor burn. An Endevco model 8511A-20k piezoresistive pressure transducer was chosen to measure the rocket chamber pressure. This report discusses a test procedure where the transducer was shocked with several thousand g's and then calibrated. A comparison of calibration values for both pre-shock and post-shock events is included. The main conclusion of the report is that the specific transducer that was tested incurred a sensitivity shift, so that the output pressure values after the post-shock event varied significantly from those of the pre-shock condition.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Endevco

    Online Contents | 1997


    Endevco

    Online Contents | 1998


    Product News: From Endevco

    Online Contents | 1998


    Products News: Endevco

    Online Contents | 1998


    Endevco stays ahead with 21st century technology

    Bogue, Robert | Online Contents | 1996