This final technical report describes the investigation and evaluation of experimental integral fuel tank sealants under laboratory conditions simulating aircraft integral fuel tanks. Materials investigated were Dow Corning 77-028, 77-085, 3M Polyester, TRW Polyimide, Polysulfide and AFML Viton. These materials were evaluated dynamically in a fillet sealed configuration. This report also describes in detail the functions, operations and problems encountered with the dynamic test apparatus that has been designed and fabricated for the purpose of evaluating experimental aircraft integral fuel tank sealants. A portion of the effort was required to diagnose deficiencies and mechanical failures of the testing equipment which resulted in the lack of conclusive data in the report.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Dynamic and Static Evaluation of Experimental Integral Fuel Tank Sealant Materials


    Beteiligte:
    J. H. Baker (Autor:in)

    Erscheinungsdatum :

    1974


    Format / Umfang :

    81 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch





    Fuel tank sealant application system

    WILKENS KEVIN MICHAEL / RAY BRIAN DUNCAN / CARTER JOHN JEFFREY et al. | Europäisches Patentamt | 2021

    Freier Zugriff

    FUEL TANK SEALANT APPLICATION SYSTEM

    WILKENS KEVIN MICHAEL / RAY BRIAN DUNCAN / CARTER JOHN JEFFREY et al. | Europäisches Patentamt | 2019

    Freier Zugriff

    SELF-FORMING FUEL TANK SEALANT SYSTEM

    HUMFELD KEITH D / BADGLEY RICHARD S | Europäisches Patentamt | 2016

    Freier Zugriff

    Self-forming fuel tank sealant system

    HUMFELD KEITH D / BADGLEY RICHARD S | Europäisches Patentamt | 2019

    Freier Zugriff