Presented in this report are the results of a study conducted to test the performance of the Mitsubishi model 5120C IR Imager as part of an automatic target acquisition (ATA) system. The study was conducted in two phases. The first was directed toward a detailed analysis of the images produced by the Mitsubishi sensor, with the aim of identifying any artifacts or characteristics that might elude the human observer but still affect the ATA system's performance. The second phase involved extensive field testing using the Mitsubishi sensor with two ATA systems: one based on the VME (Versa Module European) bus standard and the other based on a PC. The Mitsubishi sensor showed very good performance in almost all tests and appears to be an excellent choice for ATA/machine-vision applications. Frame-by-frame analysis of digitized image sequences from the Mitsubishi sensor failed to uncover any hidden problems, and several weeks of field testing with two different ATA systems demonstrated high-quality performance. FLIR, automatic target acquisition.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Mitsubishi 3-5 Micrometers IR Imager for Machine-Vision/ATA Applications


    Beteiligte:
    D. B. Hillis (Autor:in)

    Erscheinungsdatum :

    1993


    Format / Umfang :

    17 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Internal micrometers : (including stick micrometers)

    British Standards Institution | SLUB | 1950



    Detailed analysis of 4.3-micrometers earthlimb data

    Kumer, J.B. / Nadile, R.M. / Grieder, W. | Tema Archiv | 1983



    Future Vision: Mitsubishi plans for the 21st century

    British Library Online Contents | 1997