Tests were conducted on a swivel nozzle thrust deflector installed on a 91 centimeter (36 inch) low pressure ratio tip turbine fan. Fan power was supplied by a J-85 hot gas generator. The configuration was typical of a vertical/short takeoff and landing (V/STOL) aircraft propulsion system employing lift cruise fans. The performance was compared to results obtained on an 0.15 scale cold flow model. Data were obtained at fan pressure ratios from 1.1 to 1.2 and at nozzle deflections from cruise (0 deg) to VTOL (90 deg). The nozzle thrust performance was in good agreement with small scale VTOL thrust coefficients. Configurations with increased nozzle area showed lower performance. Fan operation was routine and nozzle rotation caused no circumferential distortions of the fan exit flow. Nozzle flow characteristics did not repeat small scale model results. Measured flow coefficients were smaller on the large scale test. It was concluded that lack of simulation of pressure and temperature profiles of the tip driven fan was the most probable cause of the discrepancy.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Static Tests of a Large Scale Swivel Nozzle Thrust Deflector


    Beteiligte:

    Erscheinungsdatum :

    1978


    Format / Umfang :

    44 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch