One of the sources of potential interference on spacecraft primary power lines is that of conducted transients resulting from equipment being switched on and off of the bus. Susceptibility to such transients is addressed by some version of the CS06 requirement of MIL-STD-461462. This presentation provides a summary of the history of the CS06 requirement and test method, a basis for understanding of the sources of these transients, analysis techniques for determining their worst-case characteristics, and guidelines for minimizing their magnitudes and applying the requirement appropriately.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Conducted Transients on Spacecraft Primary Power Lines


    Beteiligte:
    J. Mc Closkey (Autor:in) / J. Dimov (Autor:in)

    Erscheinungsdatum :

    2017


    Format / Umfang :

    27 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Conducted Transients on Spacecraft Primary Power Lines

    Mc Closkey, John / Dimov, Jen | NTRS | 2017