The Army needs helicopter noise source emission data for use in the Installation Compatible Use Zone (ICUZ) program and for environmental assessments. This research gathered noise source emission data for the OH-58D helicopter. The data were normalized to 250 ft for use in noise maps. The data were also used to develop sound exposure level (SEL) versus distance curves for comparison with other helicopter data. The data show that the A-weighted maximum noise level increases with airspeed for level flight, but the A weighted SEL increases only slightly. The highest A-weighted maximum level was produced by the out-of-ground effect hover. Landings produce the largest A-weighted SEL.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Operational Noise Data for OH-58D Army Helicopters


    Beteiligte:
    L. J. Benson (Autor:in) / M. J. White (Autor:in) / K. J. Murphy (Autor:in)

    Erscheinungsdatum :

    1992


    Format / Umfang :

    57 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Operational Noise Data for CH-47D and AH-64 Army Helicopters

    P. D. Schomer / A. J. Averbuch / R. Raspet et al. | NTIS | 1988


    Operational Noise Data for UH-60A and CH-47C Army Helicopters

    P. D. Schomer / A. Averbuch / R. Raspet | NTIS | 1982


    Operational problems of helicopters in army

    McCourt, F.P. | Engineering Index Backfile | 1963