The problem associated with the absorption of space tug propellants by the thermal insulation of the space shuttle orbiter during an emergency propellant dump was investigated. A test program was conducted to determine the compatibility of two space shuttle candidate insulation samples with earth-storable propellants. The was investigated. A test program was conducted to determine the compatibility of two space shuttle candidate insulation samples with earth-storable propellants. The propellant combinations used were placed in contact with the thermal insulation for two hours. Following exposure to propellants, the insulation samples were heated to 850 F for five minutes. A thermal conductivity index was determined before and after testing to evaluate possible degradation of sample chemical conductivity. (Author)
Shuttle/Agena Study. Annex C Space Shuttle Candidate Insulator/Propellant
1972
15 pages
Report
Keine Angabe
Englisch