A propane-fueled combustor was built to support the development of an alternate to the external fire test currently required for final Hazards Classification (HC). The device has the capability to provide a controlled heat flux environment of 40-400 kW/sq m (12,600-126,000 Btu/hr/sq ft). This results in a repeatable and quantifiable environment for the evaluation of the fast cook-off response of an ordnance item.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Development of Subscale Fast Cookoff Test


    Beteiligte:
    A. I. Atwood (Autor:in) / K. J. Wilson (Autor:in) / T. S. Laker (Autor:in) / E. B. Washburn (Autor:in)

    Erscheinungsdatum :

    2006


    Format / Umfang :

    11 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Development of Subscale Fast Cookoff Test (PREPRINT)

    A. Atwood / K. Wilson / T. Laker et al. | NTIS | 2006


    A Slow Cookoff Methodology Study

    Atwood, A. I. / Curran, P. O. / Kraeutle, K. J. et al. | British Library Conference Proceedings | 1999


    Large Scale Annular Cookoff Experiment (LASC)

    Asay, B. W. / Dickson, P. / Henson, B. et al. | British Library Conference Proceedings | 1999


    BEHAVIOR OF INSULATIVE MATERIAL STRUCTURES UNDER SIMULATED FAST COOKOFF ENVIRONMENT

    Koo, J. H. / Kneer, M. J. / Miller, M. J. et al. | British Library Conference Proceedings | 1991


    Subscale ENEC staging loads test

    MOCKENHAUPT, J. / WELLS, M. | AIAA | 1981