A severe fire occurred in PATH car 725 on March 16, 1982. The cause of the fire was found to be electrical in origin, but neither the initiating components nor the sequence of the fire progression could be specifically determined. The most severe damage was in the area of the Motor Controller, and it was thought to be the most likely source of the fire. The report describes the tests and analyses conducted to determine possible cause(s) of the fire. In addition, tests were made to determine possible cause(s) of the Motor Controller bolt erosion.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    PATH (Port Authority Trans-Hudson Corporation) Car Motor Controller Unit Investigation


    Erscheinungsdatum :

    1985


    Format / Umfang :

    140 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch