The results of acoustic emission (AE) monitoring of the DC-XA composite liquid hydrogen tank are presented in this report. The tank was subjected to pressurization, tensile, and compressive loads at ambient temperatures and also while full of liquid nitrogen. The tank was also pressurized with liquid hydrogen. AE was used to monitor the tank for signs of structural defects developing during the test.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Acoustic emission testing of tank floors

    Peacock, M. J. / British Institute of Non-Destructive Testing | British Library Conference Proceedings | 2003


    Acoustic Emission for Tank Bottom Monitoring

    Martin, Gary | Tema Archiv | 2013


    NASA testing large composite hydrogen tank

    Morring, Frank | Online Contents | 2014


    Railroad tank integrity testing using acoustic emission techniques

    Ternochek,S. / Physical Acoustics,US | Kraftfahrwesen | 1994


    Railroad Tank Car Integrity Testing Using Acoustic Emission Techniques

    Ternowchek, S. / ENEA; Agency: Italy | British Library Conference Proceedings | 1994