The report describes electromagnetic interference tests at the Oakland Air Route Traffic Control Center (ARTCC), Oakland, California. The tests included measurement of radiated and conducted emission from both the automated system and non-automated equipments, and radiated and conducted susceptibility of the automated system. Conducted and radiated electric and magnetic field emission from most of the automated system equipments exceeded the limits of MIL-STD-461A, but was not sufficiently high to adversely affect other equipment certified to MIL-STD-461A. Most of the automated system equipments met the susceptibility limits of MIL-STD-461A. Exceptions were the Plan View Display, Common Logic Unit, Tape Drive, M1 display and System Control Console. (Modified author abstract)
Radiofrequency Interference/Electromagnetic Interference Measurements. Oakland Air Route Traffic Control Center
1974
220 pages
Report
Keine Angabe
Englisch