The Demonstration Model (DM) Loop Heat Pipe (LHP) was tested at Goddard Space Flight Center (GSFC) during September and October, 1999. The LHP system was placed in the Dynavac 36 in. chamber in Building 4. The test lasted for about 6 weeks. The LHP was built, designed, and manufactured at Dynatherm Corporation, Inc. In Hunt Valley, MD according to GSFC specifications. The purpose of the test was to evaluate the performance of a propylene LHP for the Geoscience Laser Altimetry System (GLAS) instrument application.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Geoscience Laser Altimeter System (GLAS): Final Test Report of DM LHP TV Testing


    Beteiligte:
    C. Baker (Autor:in)

    Erscheinungsdatum :

    2000


    Format / Umfang :

    30 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch





    The geoscience laser altimeter system (GLAS)

    Abshire, James B. / Smith, James C. / Schutz, Bob E. | NTRS | 1998


    The Geoscience Laser Altimeter System (GLAS)

    Abshire, J. B. / Smith, J. C. / Schutz, B. E. et al. | British Library Conference Proceedings | 1998


    Testing of the Geoscience Laser Altimeter System (GLAS) prototype loop heat pipe

    Douglas, Donya / Ku, Jentung / Kaya, Tarik | AIAA | 1999


    Testing of the Geoscience Laser Altimeter System (GLAS) Prototype Loop Heat Pipe

    Douglas, D. / Ku, J. / Kaya, T. et al. | British Library Conference Proceedings | 1999