This final report describes and provides the data on the reduced voltage (108 VAC) and restart testing of the 1-Watt Integral Stirling Cooler. the 1-Watt Integral Cooler (HD-1033B/C/D) is currently used in the M1 FLIR, M60 FLIR, and the Advanced Attack Helicopter FLIR. The cooler specification requires that the cooler operate from 115 to 119 VAC. Because of the potential of lower voltage operation in some systems, C2NVEO evaluated the cooler performance and restartability at environmental extremes with 108 VAC. The coolers successfully passed all testing at all environmental conditions using both voltages. (RRH)


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Reduced Voltage and Restart Testing of the 1-Watt Integral Cryogenic Cooler (HD-1033B/C/D)


    Beteiligte:
    H. Dunmire (Autor:in) / J. Shaffer (Autor:in)

    Erscheinungsdatum :

    1989


    Format / Umfang :

    94 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch






    Fractional watt Vuilleumier cryogenic refrigerator

    Miller, W. S. / Potter, V. L. | NTRS | 1973


    Cryogenic Testing of Planck Sorption Cooler Test Facility

    Zhang, B. / Pearson, D. / Borders, J. et al. | British Library Conference Proceedings | 2005


    Cryogenic Testing of Planck Sorption Cooler Test Facility

    Zhang, B. / Pearson, D. / Borders, J. et al. | Springer Verlag | 2005