Two electrohydraulic vibration isolation systems were designed and fabricated to reduce the vertical vibrations transmitted to the XH-51N research helicopter cabin at the blade passage frequency (18 Hz) and its first harmonic (36 Hz). Hydraulic power and electrical control are provided to two separate servoactuators from a common power supply and control electronics package located behind the pilot's seat. One servoactuator is installed between the cabin and fuselage and replaces an existing passive spring. A second servoactuator is mounted between the existing seat and cabin floor. Both servoactuators incorporate a mechanical failsafe design. The control electronics circuitry provides automatic tracking of the blade passage frequency. Results of laboratory, environmental and ground vibration tests employing an XH-51A stripped down helicopter fuselage show that the active cabin isolator reduces the vertical vibrations transmitted from the fuselage attachment point to the cabin attachment point at 18 and 36 Hz (or as an alternative, 6 Hz) by better than 90 percent. (Author)
Design, Fabrication and Testing of Two Electrohydraulic Vibration Isolation Systems for Helicopter Environments