Qualification testing of the environmental data recorder (EDR) was successfully completed. The purpose of this test was to qualify the EDR so that it could monitor segments shipped via railcar from Utah to Kennedy Space Center (KSC). The tests consisted of a transportation and a functional test. The transportation test verified EDR operation in its intended environment. The functional test verified EDR accuracy. Data from the functional test showed that the EDR accuracies complied with requirements. Since the EDR meets or exceeds all of its test objectives, it was successfully qualified. It is recommended that the EDR replace the transportation monitoring unit (TMU). A description of the qualification procedure is presented.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Environmental Data Recorder (EDR) Qualification


    Beteiligte:
    R. A. Danforth (Autor:in)

    Erscheinungsdatum :

    1991


    Format / Umfang :

    112 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Environmental Data Recorder (EDR) qualification

    Danforth, Richard A. | NTRS | 1991


    Data recorder

    Online Contents | 1994



    Dynamic Environmental Qualification Techniques

    J. H. Wafford / G. Haidl / C. Lodge et al. | NTIS | 1979