A series of marine fouling experiments was conducted at Freeport, Texas, on two single-pass titanium heat exchangers. The exchangers, which were constructed with commercially pure titanium tubes (5/8-inch (1.59-centimeter)) outside diameter by 30-inch (76.3-centimeter length) and 6Al-4V alloy tube sheets and headers, were operated on natural seawater. One of the exchangers was fed electrolytically chlorinated seawater, while the other was run with untreated seawater feed. Velocity and chlorination levels were varied to determine the effect of these two variables on fouling of the titanium surfaces. Operating conditions similar to those that might be expected in shipboard heat exchanger/condenser usage were modeled.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Marine Fouling of Titanium Heat Exchangers


    Beteiligte:
    W. L. Adamson (Autor:in)

    Erscheinungsdatum :

    1976


    Format / Umfang :

    28 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Marine fouling of titanium heat exchangers

    Adamson, W. | Tema Archiv | 1976


    Fouling in naval condensers and heat exchangers

    Macnair, E.J. | Tema Archiv | 1979


    Probe Measures Fouling As In Heat Exchangers

    Marner, Wilbur J. / Macdavid, Kenton S. | NTRS | 1990


    Air side fouling of compact heat exchangers

    Mason, D. J. / Douch, N. / Heikal, M. R. et al. | British Library Conference Proceedings | 2002


    Estimation and Control of Fouling in Heat Exchangers