This study is part of a greater body of research on the electromagnetic compatibility in the railway environment throughout Europe. In particular, this study focuses on the broadcasting services as a victim area and identifies the electromagnetic interference threats in the railway environment. After the definition of the pantograph arcing as the worst-case scenario in terms of interference to these services, a test method was carried out in a controlled environment in order to examine the characteristics of these transient arcing events. It was found out that the power radiated is a broadband signal and the high levels of the radiated emissions require further investigation and examination, including addition to the railway standards that define the cross-domain interoperability of equipment, rolling stock and fixed installations in the railway environment.


    Zugriff

    Zugriff über TIB


    Exportieren, teilen und zitieren



    Titel :

    Test of rolling stock electromagnetic compatibility for cross-domain interoperability


    Beteiligte:
    Karadimou, Eva (Autor:in) / Armstrong, Rob (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    2016-02-01


    Format / Umfang :

    7 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch




    Test of rolling stock electromagnetic compatibility for cross‐domain interoperability

    Karadimou, Eva / Armstrong, Rob | Wiley | 2016

    Freier Zugriff


    About the management of electromagnetic compatibility in the railway rolling stock domain for high frequencies

    Maumy, F. / Association of American Railroads| Railway Technical Research Institute, Japan | British Library Conference Proceedings | 1994