In this paper, a new technique for stator winding inter-turn fault detection in current controlled Permanent Magnet Synchronous Machines is proposed. The method is based on the online extraction of the second harmonic component of the voltage reference vector in the d-q frame. It will be shown that the amplitude of this harmonic depends on the inter-turn fault severity and the fault detection is realized by comparing the amplitude of the second harmonic to a threshold. This is a low cost method in CPU time. The experimental results show the validity of the proposed method.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Stator winding inter-turn fault detection using control voltages demodulation


    Beteiligte:
    Boileau, T. (Autor:in) / Leboeuf, N. (Autor:in) / Nahid-Mobarakeh, B. (Autor:in) / Meibody-Tabar, F. (Autor:in)


    Erscheinungsdatum :

    01.06.2012


    Format / Umfang :

    740811 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch