The Cascaded H-Bridge topology has in recent years become popular for use in medium voltage drives. The reliability of this topology however is of concern due to the large number of semiconductor switches. The natural redundancy possessed by the CHB topology can only be realized if failed devices may be identified and removed from the system. In this paper a fault diagnostic method for open switch fault is proposed. The method is based on the prediction of the active and zero voltage states of each module. With the proposed method, the exact location of the switch under fault in an H-bridge module can be determined quickly. The performance of the proposed technique has been verified through simulation.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Fast fault detection of open power switch in cascaded H-bridge multilevel inverters


    Beteiligte:


    Erscheinungsdatum :

    2016-06-01


    Format / Umfang :

    468730 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch





    Finite control set-model predictive control for power converters multilevel symmetric cascaded H-bridge inverters-fed drive

    Innocent, Leka Alain / Lamine, Doumbia Mamadou / Joseph, Song-Manguelle et al. | IEEE | 2018



    Improved cascaded multilevel battery inverters with phase-to-phase SOC balancing capability