In this paper, we proposed a new method to demonstrate a practical Ar/sub 2/ laser by use of an ultrashort-pulse high-intensity laser. Characteristics of the initial electrons produced by an optical-field-induced ionization (OFI) process were controlled by appropriate choice of the high-intensity laser parameters. These controlled electrons then initiated the Ar/sub 2/ production kinetics. To increase a gain-length product, an Ar-filled hollow fiber was used to extend the excitation plasma length up to 30 cm, where the high-intensity laser and 126-nm VUV radiation were propagated.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Vacuum ultraviolet argon excimer laser pumped by high-intensity laser-produced electrons


    Beteiligte:
    Kubodera, S. (Autor:in) / Morita, Y. (Autor:in) / Higashiguchi, T. (Autor:in) / Rajyaguru, C. (Autor:in) / Sasaki, W. (Autor:in)


    Erscheinungsdatum :

    2005-01-01


    Format / Umfang :

    198063 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch




    Argon fluoride excimer laser ablation of cornea

    Pettit, George H. / Ediger, Marwood N. / Weiblinger, Richard P. | SPIE | 1992


    Discharge pumped VUV rare-gas excimer laser

    Kubodera, S. / Higashiguchi, T. / Sasaki, W. | IEEE | 2002


    Ce^3^+:LuLiF~4 as an Excimer-Laser-Pumped Ultraviolet Tunable Solid-State Amplifier

    Sarukura, N. / Liu, Z. / Segawa, Y. et al. | British Library Conference Proceedings | 1994


    MP3 Discharge Pumped VUV Rare-Gas Excimer Laser

    IEEE | British Library Conference Proceedings | 2002