In this article, the transient-state lumped parameter thermal model (LPTM) of the wound field switched flux (WFSF) machine is characterized for the first time. The modeling methodology for the LPTM is given in detail, including the process of determining the parameters of the LPTM, based on which two LPTMs are compared with the experiments, i.e., the LPTM-I and LPTM-II without and with consideration of the practical winding position in the stator slot. It is found that the practical positions of the dc and ac coils in the slots are important to improve the accuracy of the LPTM, due to the existence of slot empty space caused by overlapped dc and ac windings. By considering the practical positions of the dc and ac coils in the slots, the maximum value of the absolute error between the LPTM model predicted temperature and the measured values of the ac winding are 3.4 °C, 5.23 °C, 3.18 °C, and 5.22 °C under dc test, steady-state test, cycling test-I, and cycling test-II, respectively, while they are 3.95 °C, 2.00 °C, 2.28 °C, and 4.89 °C for the dc winding temperature error. The average value of the absolute error between the LPTM model predicted temperature and the measured values of the ac winding are 0.88 °C, 1.25 °C, 0.85 °C, and 1.87 °C under dc test, steady-state test, cycling test-I, and cycling test-II, respectively, while they are 1.08 °C, 1.47 °C, 1.06 °C, and 2.73 °C for the dc winding temperature. The temperature of the WFSF machine during a 9-h experiment can be predicted in 27.8 s by the LPTM, which has a more than 1100 times faster calculation speed.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    A Transient-State Lumped Parameter Thermal Model for Brushless Wound Field Switched Flux Machines


    Beteiligte:
    Wu, Zhongze (Autor:in) / Zhang, Wentao (Autor:in) / Fan, Ying (Autor:in) / Hua, Wei (Autor:in) / Cheng, Ming (Autor:in)


    Erscheinungsdatum :

    01.03.2024


    Format / Umfang :

    5624712 byte




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Axial flux permanent magnet brushless machines

    Gieras, Jacek F. / Wang, Rong-Jie / Kamper, Maarten J. | TIBKAT | 2008


    A Lumped Parameter Thermal Model for Single-Sided AFPM Machines With Experimental Validation

    Burke, Richard / Giedymin, Artur / Wu, Zhongze et al. | IEEE | 2020


    Lumped Parameter Transient Thermal Model of Motor Considering Temperature and Flow Rate of Cooling Water

    Ni, Jimin / Li, Juncheng / Xu, XiaoChuan | SAE Technical Papers | 2019


    Lumped Parameter Transient Thermal Model of Motor Considering Temperature and Flow Rate of Cooling Water

    Li, Juncheng / Ni, Jimin / Xu, XiaoChuan | British Library Conference Proceedings | 2019


    Investigation of axial field partitioned stator switched flux machines

    Zhu, Z. Q. / Zhou, Y. J. / Chen, J.T. | IEEE | 2015