This paper describes work undertaken to assess, at an early stage of a project, the impact of a fuse blow event on the electrical power quality of the spacecraft. This allows to simulate and predict the expected transient, to define proper countermeasure already during the design phase of the satellite, to avoid tests and verification directly on the hardware and mainly to avoid to discover criticalities during the satellite integration phase that could be too late. Spice simulations were undertaken and the results were compared to measurements taken on a scaled-down testbed representative of a planned architecture for a project at OHB. The work presented focuses on fuse modelling based on electrical parameters, combining the available datasheet information and test result at different current level characterizing the melting and arcing time. The arcing behavior of the fuse is thus modelled, with a new approach, as an electrical resistance increasing exponentially.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Simplified Spice Model for fuse Blow Analysis


    Beteiligte:
    Alia, S. (Autor:in) / Caudepon, J. (Autor:in) / Larde, C. (Autor:in) / Tosti, M. (Autor:in) / Trougnou, L. (Autor:in)


    Erscheinungsdatum :

    2022-05-23


    Format / Umfang :

    1075128 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    grip retainer for junction block low profile slow blow fuse

    KIM WOO YOUNG | Europäisches Patentamt | 2021

    Freier Zugriff



    FUSE

    KATAYAMA KAZUNARI | Europäisches Patentamt | 2017

    Freier Zugriff