In this paper, the dynamic and electric analysis of a novel electrostatically actuated microdevice is presented. This device consist of an arrangement of four parallel microcantilevers, which is fed with 1 V. The analysis was carried out by Finite Element Method (FEM) in Ansys Workbench in order to obtain: current intensity, temperature distribution, Joule effect, structural deformation, natural frequency, and reaction force, which characterize the microgripper performance. The material used in the analysis was Silicon. A thermoelastic model, that describes the behavior mechanical of the device, is developed. The device had an initial gap of 28 µm and a final gap of ~ 4 µm, the force of subjection in grippers is 0.4 µN.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Design and FEM Analysis of a New and Simple Electro-Thermal Actuated Microgripper


    Beteiligte:


    Erscheinungsdatum :

    2017-11-01


    Format / Umfang :

    278097 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    A Parametric Study on Electro Thermally Actuated Novel Compliant Microgripper

    Bharadwaj, Kishor / Elsen, Renold / Ramesh, Thillaigovindan | SAE Technical Papers | 2019


    Novel Microgripper based on a Chevron Actuator and a Simple Compliance Arrangement

    Tecpoyotl-Torres, M. / Rodriguez-Fuentes, S. F. / Vera-Dimas, J. G. et al. | IEEE | 2020




    Design and validation of a single-SOI-wafer 4-DOF crawling microgripper

    Verotti M. / Bagolini A. / Bellutti P. et al. | BASE | 2019

    Freier Zugriff