This paper presents a dynamic load-shedding scheme that uses a network of non-intrusive load monitors (NILMs). These devices, which can monitor the status of multiple loads using only a single set of aggregate voltage and current transducers, can log important real-time information about individual loads. This information can be used as part of a dynamic load-shedding scheme. The proposed approach is tested using a simulation model constructed in the Alternative Transients Program (ATP). Results demonstrate its effectiveness.
Dynamic load shedding for shipboard power systems using the non-intrusive load monitor
01.04.2009
630658 byte
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Shipboard Applications of Non-Intrusive Load Monitoring
NTIS | 2004
|NON-INTRUSIVE LOAD MONITORING FOR SHIPBOARD LOG GENERATION
TIBKAT | 2019
|