In this paper, specially assembled connectors concatenated were tested under long term reliability tests by polishing ferrules endface as just exceeding the border value of the above proposed parameters. The proposed dimensions were experimentally verified. Water immersion tests done for both GCF-using connectors and ZrF-using connectors showed that GCF is highly reliable in the severest outside conditions like FTTH.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Reliability of glass-ceramic ferrules in the severest conditions


    Beteiligte:
    Mitachi, S. (Autor:in) / Yonekawa, N. (Autor:in) / Shioda, M. (Autor:in) / Nakajima, S. (Autor:in) / Takeuchi, H. (Autor:in)


    Erscheinungsdatum :

    01.01.2004


    Format / Umfang :

    152365 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Reliability of Glass-Ceramic Ferrules in the Severest Conditions

    Lasers and Electro-optics Society (Institute of Electrical and Electronics Engineers) | British Library Conference Proceedings | 2004


    Physical contact conditions of glass-ceramic ferrules for optical connectors

    Mitachi, S. / Yonekawa, N. / Hashimoto, K. | IEEE | 2002




    Reliability Test Results for Physical Contact between Connectors Assembled with Different Material Ferrules

    IEEE Lasers and Electro-optics Society | British Library Conference Proceedings | 2005