Tests were conducted on 1:15- and 1:50-scale models to determine the cause of, and to make modifications for eliminating, tainter gate bouncing experienced under certain flow conditions at Barkley Dam. The 1:15-scale model determined the flow conditions that caused the bouncing, and the hydraulic loads and load variations acting on the gate during this occurrence . Hoist load fluctuations in excess of 140 kips were measured. The bottom of the tainter gate was modified to various configurations in an effort to alter the flow patterns causing the bouncing, but these modifications were relatively ineffective in reducing the hoist loads. A 1:50-scale model was incorporated into the study to determine the effect of the downstream spillway piers and the stilling basin on the flow conditions. Test results indicated that increasing the length of the spillway piers by 20 ft downstream reduced the surging of flow associated with the bouncing. A minimum top elevation of these extended piers was determined to be 345.0. The hoist loads were then measured with the piers placed in the 1:15-scale model. The maximum hoist load fluctuation was reduced by over 100 kips from 140 kips with the original design to 40 kips with the piers extended. The 1:15-scale model was also used to determine the hydraulic loads that occur as the emergency bulkheads are lowered under flowing water conditions. The bulkhead tests revealed that the loads on the hoist due to hydraulic forces were not extreme for heads on the gate sill of 21, 29, and 34 ft as long as the bulkhead was lowered at the prototype hoisting speed of 4 to 6 ft/min. Unstable loads were encountered at heads of 29 and 34 ft on the gate sill when the bulkhead was held at stationary positions above the crest with high tailwater conditions.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Barkley Dam Spillway Tainter Gate and Emergency Bulkheads, Cumberland River, Kentucky: Hydraulic Model Investigation



    Erschienen in:

    Erscheinungsdatum :

    1983


    Format / Umfang :

    7403783


    Medientyp :

    Report


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :


    Prototype Gate Vibration Tests, Barkley Dam, Cumberland River, Kentucky

    Hart, Ellis Dale / Hite, John E. Jr. | HENRY – Bundesanstalt für Wasserbau (BAW) | 1979

    Freier Zugriff

    Barkley Lock Prototype Tests, Cumberland River, Kentucky

    Neilson, Frank Murray | HENRY – Bundesanstalt für Wasserbau (BAW) | 1975

    Freier Zugriff

    Submersible-Type Tainter Gate for Spillway, Peoria Lock and Dam: Hydraulic Model Investigation

    Cooper, Deborah R. | HENRY – Bundesanstalt für Wasserbau (BAW) | 1991

    Freier Zugriff

    Submersible-Type Tainter Gate for Spillway, Marseilles Lock and Dam: Hydraulic Model Investigation

    Cooper, Deborah R. | HENRY – Bundesanstalt für Wasserbau (BAW) | 1989

    Freier Zugriff

    Navigation Conditions on the Lower Cumberland River, Kentucky: Hydraulic Model Investigation

    Shows, Louis J. / Franco, John J. | HENRY – Bundesanstalt für Wasserbau (BAW) | 1979

    Freier Zugriff