AbstractWe have installed the first MAGDAS magnetometer at Fayum in Egypt. The ambient temperature in the initial sensor house varied more than ±4°C in one day (24h period). This variation made the magnetic data useless. To correct this problem, (1) a new sensor house was re-constructed which reduced the diurnal variation to less than ±1°C, and (2) the “Uozumi Temperature Correction Method” was introduced. As a result, good data is now arriving in real time at a central facility in Japan.