Abstract Prolonged weightlessness is associated with declines in musculoskeletal, cardiovascular, and sensorimotor health. Consequently, in-flight countermeasures are required to preserve astronaut health. We developed and tested a novel exercise countermeasure device (CCD) for use in spaceflight with the aim of preserving musculoskeletal and cardiovascular health along with an incorporated balance training component. Additionally, the CCD features a compact footprint, and a low power requirement. Methods: After design and development of the CCD, we carried out a training study to test its ability to improve cardiovascular and muscular fitness in healthy volunteers. Fourteen male and female subjects (41.4±9.0 years, 69.5±15.4kg) completed 12 weeks (3 sessions per week) of concurrent strength and endurance training on the CCD. All training was conducted with the subject in orthostasis. When configured for spaceflight, subjects will be fixed to the device via a vest with loop attachments secured to subject load devices. Subjects were tested at baseline and after 12 weeks for 1-repetition max leg press strength (1RM), peak oxygen consumption (VO2peak), and isokinetic joint torque (ISO) at the hip, knee, and ankle. Additionally, we evaluated subjects after 6 weeks of training for changes in VO2peak and 1RM. Results: VO2peak and 1RM improved after 6 weeks, with additional improvements after 12 weeks (1.95±0.5, 2.28±0.5, 2.47±0.6Lmin−1, and 131.2±63.9,182.8±75.0, 207.0±75.0kg) for baseline, 6 weeks, and 12 weeks, respectively. ISO for hip adduction, adduction, and ankle plantar flexion improved after 12 weeks of training (70.3±39.5, 76.8±39.2, and 55.7±21.7Nm vs. 86.1±37.3, 85.1±34.3, and 62.1±26.4Nm, respectively). No changes were observed for ISO during hip flexion, knee extension, or knee flexion. Conclusions: The CCD is effective at improving cardiovascular fitness and isotonic leg strength in healthy adults. Further, the improvement in hip adductor and abductor torque provides support that the CCD may provide additional protection for the preservation of bone health at the hip.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Development of an integrated countermeasure device for use in long-duration spaceflight


    Beteiligte:
    Streeper, T. (Autor:in) / Cavanagh, P.R. (Autor:in) / Hanson, A.M. (Autor:in) / Carpenter, R.D. (Autor:in) / Saeed, I. (Autor:in) / Kornak, J. (Autor:in) / Frassetto, L. (Autor:in) / Grodsinsky, C. (Autor:in) / Funk, J. (Autor:in) / Lee, S.M.C. (Autor:in)

    Erschienen in:

    Acta Astronautica ; 68 , 11-12 ; 2029-2037


    Erscheinungsdatum :

    2010-11-01


    Format / Umfang :

    9 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch





    Exercise Countermeasure for Spaceflight

    V. A. Couvertino / H. Sandler | NTIS | 1995


    Development of an Integrated Sensorimotor Countermeasure Suite for Spaceflight Operations

    Bloomberg, J. J. / Batson, C. D. / Caldwell, E. E. et al. | NTRS | 2017


    Locomotor Dysfunction after Spaceflight: Characterization and Countermeasure Development

    Mulavara, A. P. / Cohen, H. S. / Peters, B. T. et al. | NTRS | 2007