Highlights A DORIS ground antenna Alcatel PSV model selection has 15 mm height impact. The recent IDS model performs better than the old one in the term of post-fit observation residuals. The Alcatel stations post-fit residuals are higher in low elevations but lower in high elevations, when compared to the Starec stations post-fit residuals.

    Abstract The DORIS ground antenna phase center variation (PCV) modeling is an important factor of the DORIS solution accuracy and affects also the DORIS solutions employed in the ITRF2020 realization. There are two different elevation dependent models available for the Alcatel antenna, called here 1.0 and 2.0. For the Starec antenna we have only one PCV model. We demonstrate the effect of the Alcatel PCV model selection, reaching a value around 15 mm in the estimated DORIS station height. The post-fit Doppler observation residual analysis proved a better performance of the residuals derived from the solution employing Alcatel PCV model 2.0, particularly in several specific elevation intervals over 50 degrees. The elevation dependent systematics in the residuals have been proven by the separation of the ascending and descending portions of the residuals. The residual mean calculated for the elevation intervals reached values with a mutually opposite sign for the ascending and descending observations. Moreover, we have compared the residuals of the Starec and Alcatel stations, whereas the Starec residual RMS was lower for elevations approximately under 50 degrees, the Alcatel residual RMS was lower for higher elevations. This result could relate to an eventual Starec PCV model imperfection at higher elevations. To check the compatibility of the Starec and Alcatel PCV models impact on the station height, we have performed the comparison of the measured vertical component of the DORIS-DORIS local ties to a value calculated from the DORIS observations. The pairs of the Alcatel-Starec stations were the object of interest. When repeating the experiment with both Alcatel models 1.0 and 2.0, we have found a similar level of agreement of the measured and observed/computed height difference, but with the opposite sign. The average difference reached 8.7 ± 2.5 mm for Alcatel PCV model 1.0 and −7.2 ± 2.4 mm for Alcatel PCV model 2.0.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    DORIS Alcatel ground antenna: Evaluation of the phase center variation models


    Beteiligte:

    Erschienen in:

    Erscheinungsdatum :

    2022-02-16


    Format / Umfang :

    14 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch




    DORIS Starec ground antenna characterization and impact on positioning

    Tourain, C. / Moreaux, G. / Auriol, A. et al. | Elsevier | 2016




    DORIS Data Center at the CDDIS

    C. E. Noll / M. Dube | NTIS | 2000


    Alcatel Stellwerkstechnik

    Staffel, G. / Böhm, W. | Tema Archiv | 2000