Air conditioning system for new P and O passenger ship is served by 70 central conditioning units, with fans handling 50,000 tons of air/day; 4 2-stage centrifugal compressors operating on Refrigerant-11, each directly coupled to single stage steam turbine of 547 bhp, condition air; 4 8-cyl compressors directly coupled to electric motors of 100 bhp, operating on Refrigerant-12, deal with 19 independently cooled provision chambers.