Steam accumulator and ejector system used in support of testing aerospace systems at Arnold Air Force Station, Tennessee, is described; stored steam provides short term flow rate of 15,500,000 lb/hr through ejectors to simulate high altitude conditions; operation of accumulator, boiler, fuel storage and piping, and steam system components.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Stored steam drives ejectors in high altitude tests of earthbound rocket engines


    Weitere Titelangaben:

    Heating, Piping Air Conditioning


    Beteiligte:

    Erschienen in:

    Erscheinungsdatum :

    1968


    Format / Umfang :

    6 pages


    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch


    Schlagwörter :


    High-altitude tests of rocket engines in ground test facilities

    Smith, Jr., R.E. / Ferrell, Jr., J. | Engineering Index Backfile | 1964


    High-Altitude Tests of Rocket Engines in Ground Test Facilities

    Ferrell, Joel / Smith, Robert E. | SAE Technical Papers | 1964


    The Huygens probe: An earthbound rehearsal