Holt Lock will be 110 ft wide, 670 ft long, and will provide maximum lift of 63.6 ft; tests were conducted in 1 to 25-scale model of filling and emptying system to determine its adequacy and relative merits of interlaced and split floor lateral arrangements; tests also were conducted in 1 to 15-scale model of one of 12.5× 12. 5-ft culvert valves to develop optimum valve design from standpoint of loads on valve hoisting mechanism; lock filling and emptying system will consist of single port intakes and outlets in river side of riverwall, longitudinal culvert in each wall, and interlaced floor laterals in lock chamber.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Lock filling and emptying system, Holt Lock and Dam Warrior river, Alabama


    Weitere Titelangaben:

    U S Waterways Experiment Station -- Tech Report


    Beteiligte:
    Murphy, T.E. (Autor:in) / Ables, Jr., J.H. (Autor:in)


    Erscheinungsdatum :

    1965


    Format / Umfang :

    119 pages


    Medientyp :

    Report


    Format :

    Print


    Sprache :

    Englisch


    Schlagwörter :



    Prototype Filling and Emptying System Measurements, New Bankhead Lock, Black Warrior River, Alabama

    Tool, Allen R. / United States. Army. Corps of Engineers. Mobile District. | HENRY – Bundesanstalt für Wasserbau (BAW) | 1980

    Freier Zugriff

    Navigation Conditions and Filling and Emptying System, New Bankhead Lock, Black Warrior River, Alabama: Hydraulic Model Investigation

    Oswalt, Noel R. / Ables, Jackson H. Jr. / Murphy, Thomas E. et al. | HENRY – Bundesanstalt für Wasserbau (BAW) | 1972

    Freier Zugriff