The calculation of pipeline networks with Q- equations involves the determination of flow rates of liquid flowing through pipes by solving the system of equations comprising the mass conservation equation and the energy conservation equations written along the loops and pseudo-loops. The paper presents an application that solves a network comprising a PRV (Pressure reduction valve). In case of mounting a PRV in the device it takes place a leap of energy and energy conservation equation along a loop is no longer valid. The literature recommends fitting a fictitious tank instead of the device and writing the energy conservation equation in the pseudo-loop.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    The calculation of pipeline network comprising pressure reduction valve (PRV) with Q-equation


    Beteiligte:
    Alexandru Ioan (Autor:in)


    Erscheinungsdatum :

    2018




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Unbekannt




    Liquid pipeline pressure exhaust valve

    WU JIAXIANG / SHEN FENGCUN / LIU YAMIN et al. | Europäisches Patentamt | 2023

    Freier Zugriff

    Gate valve achieving sealing through cavity air pressure and vacuum pipeline with gate valve

    MAO KAI / LIU DEGANG / HAN SHUCHUN et al. | Europäisches Patentamt | 2020

    Freier Zugriff

    Pipeline stop valve

    JIANG XIAOPING / JIANG JIALEI | Europäisches Patentamt | 2023

    Freier Zugriff


    Butterfly valve convenient to connect with pipeline

    WENG YUANSI | Europäisches Patentamt | 2023

    Freier Zugriff