Remote photoplethysmography (rPPG) is now becoming a new trend method to measure human physiological parameters. Especially due to it noncontact measurement which safe dan suitable to use in this new era condition. Pulse rate variability (PRV) and respiration rate (RR) included as parameters can be measured by using rPPG. PRV and RR are used to measure both physical and psychological wellness of the subject. However, current performance challenges in rPPG algorithm in measuring PRV and RR are illuminance invariant and motion. Especially in different light condition which represent real-life environment, signal-to-noise ratio (SNR) will be affected and directly reduce the measurement accuracy. Therefore in this study, we develop rPPG algorithm and then investigate the performance rPPG in different illuminance scenarios. We perform PRV and RR measurement under each scenario. On this study, for the pulse signal extraction, we were using algorithm is based on the modification of plane orthogonal-to-skin (POS) algorithm. While, for respiration signal extraction is done in CIE Lab color space. Our experimental results show the mean absolute error (MAE) of each measured parameters are 3.25 BPM and 2 BPM for PRV and RR respectively compared with clinical apparatus. The proposed method proved to be more reliable to use in real environments measurement. However, limitation of our proposed algorithm is still running in offline mode, hence for the future we want try to make our algorithm run in real time.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Illuminance Color Independent in Remote Photoplethysmography for Pulse Rate Variability and Respiration Rate Measurement



    Erscheinungsdatum :

    2023-09-10


    Anmerkungen:

    doi:10.30630/joiv.7.3.1176
    JOIV : International Journal on Informatics Visualization; Vol 7, No 3 (2023); 920-926 ; 2549-9904 ; 2549-9610



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :

    DDC:    629




    A Noncontact Measurement of Cardiac Pulse Based on PhotoPlethysmoGraphy

    Wu, Xiaohua / Li, Xin / Xu, Yulin et al. | Springer Verlag | 2017


    Illuminance adjusting apparatus, illuminance adjusting method, and computer program

    TANI KENTARO | Europäisches Patentamt | 2021

    Freier Zugriff

    An Illuminance-Reflectance Model for Nonlinear Enhancement of Color Images

    Li Tao, / Tompkins, R. / Asari, V.K. | IEEE | 2005


    ILLUMINANCE ADJUSTMENT DEVICE, ILLUMINANCE ADJUSTMENT METHOD AND COMPUTER PROGRAM

    TANI KENTARO | Europäisches Patentamt | 2019

    Freier Zugriff

    ILLUMINANCE ADJUSTING APPARATUS, ILLUMINANCE ADJUSTING METHOD, AND COMPUTER PROGRAM

    TANI KENTARO | Europäisches Patentamt | 2020

    Freier Zugriff