In this report an actuator fault-tolerant control (FTC) strategy based on set separation is presented. The proposed scheme employs a bank of observers which match the different fault situations that can occur in the plant. Each of these observers has an associated estimation error with a distinctive behaviour when a estimator matches the current fault situation of the plant. With this information from each observer, a fault diagnosis and isolation (FDI) module is able to reconfigure the control loop by selecting the appropriate stabilising controller from a bank of precomputed control laws, each of them related to one of the considered fault models. The control law consists of a reference feedforward term and a feedback gain multiplying the state estimate provided by the matching observer. The decision criteria of the FDI is based on the computation of sets towards which the output estimation errors related to each fault scenario and for each control configuration converge. Conditions for the design of the FDI module and for fault tolerant closed-loop stability are given, and the effectiveness of the approach is illustrated by means of a numerical example. ; This work was supported by the project 'Integración de técnicas avanzadas de modelado, control y supervisión aplicadas a la gestión del ciclo integral del agua' (4797).
Actuator fault-tolerant control based on set separation
2008-01-01
Sonstige
Elektronische Ressource
Englisch
DDC: | 629 |
Fault-Tolerant Control for Launch Vehicle Actuator Based on Adaptive Control
Springer Verlag | 2021
|Actuator fault monitoring and fault tolerant control in distillation columns
British Library Online Contents | 2017
|