Acoustic noise becoming ever more obnoxious radiated by voltage source inverter fed induction motor drive in modern and industrial applications. The drive utilized for industrial and modern applications should use “spread spectrum” innovation known as Random pulse width modulation (PWM) algorithms where acoustic noise emanates through the machine should be critically concerned. This paper illustrates three types of random PWM control algorithms with fixed switching frequency namely 1) Random modulating PWM 2) Random carrier PWM and 3) Random modulating-carrier PWM. The spectrum plots of the motor stator current demonstrate the strength and robustness of the proposed PWM algorithms. To affirm the proposed algorithms, experimental tests have been conducted using dSPACE rt1104 control board on a v/f control three phase induction motor drive fed by DC link cascaded multilevel inverter.
Level Shifted Carrier Signal Based Scalar Random Pulse Width Modulation Algorithms for Cascaded Multilevel Inverter Fed Induction Motor Drive
2019-06-02
oai:zenodo.org:3346698
International Journal of Electrical, Electronic and Communication Sciences 12.0(7)
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC: | 629 |
Chip Implementation of Digital Scalar Space-vector Pulse Width Modulation for Induction Motor Drive
Online Contents | 2011
|Switching Circuit and Drive for Cascaded Multilevel Inverter
TIBKAT | 2019
|Switching Circuit and Drive for Cascaded Multilevel Inverter
Springer Verlag | 2019
|MOTOR OPERATING REGION BASED RANDOM PULSE WIDTH MODULATION
Europäisches Patentamt | 2019
|