OBJECTIVE: The lack of haptic feedback (HF) in robotic surgery is one of the major concerns of novice surgeons to that field. The superior visual appearances acquired during robotic surgery may give clues that make HF less important. METHODS: We surveyed 52 individuals on their perception of HF during robotic surgery. The first group of 34 surgically inexperienced people used the da Vinci robot for their first time (drylab). The second group included 8 laparoscopic surgeons with experience up to a fifth robotic operation. The third group included 10 surgical experts with substantial experience (150-650 robotic cases). Visual analog assessment was made of perception of HF, how much HF was missed, how much the absence of HF impaired the operators' level of comfort. Robotic experts were asked if complications have occurred as a result of a lack of HF. RESULTS: Of the first group, 50% reported the perception of HF, as did 55% of the second group and 100% of the third group (difference between group 1 and group 3: p < 0.05). The first group missed HF for 6.5; the second group for 4.3, and the third group for 4 (difference between groups 1 and 3: p < 0.05). The surgical experts claimed to have missed HF for 7.2 s when they first started robotic surgery (Difference to now: p < 0.05). The lack of HF caused discomfort for the first group of 4; for the second group of 4,4, and for the third group of 2,6. One complication was reported by the robotic experts as resulting from the lack of HF. CONCLUSIONS: The data support the conclusion that even beginners quickly experience the perception of HF when performing robotic surgery. With more experience, perception of HF and the level of comfort with robotic surgery increases significantly. This perception of HF makes "real" HF less important and demonstrates that its importance is overestimated by novices in robotic surgery.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Visual clues act as a substitute for haptic feedback in robotic surgery


    Beteiligte:
    Hagen, M. E. (Autor:in) / Meehan, J. J. (Autor:in) / Inan, Ihsan (Autor:in) / Morel, Philippe (Autor:in)

    Erscheinungsdatum :

    01.01.2008


    Anmerkungen:

    unige:824
    ISSN: 0930-2794 ; Surgical endoscopy, vol. 22, no. 6 (2008) p. 1505-1508


    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :

    DDC:    629 / 796



    Visual clues act as a substitute for haptic feedback in robotic surgery

    Hagen, M. E. / Meehan, J. J. / Inan, Ihsan et al. | BASE | 2008

    Freier Zugriff

    Haptic-feedback-based robotic teleparamedics

    Zeltser, Gregory / Forrester, Thomas / Shnitser, Paul I. et al. | SPIE | 2002


    Haptic-feedback-based robotic teleparamedics [4715-04]

    Zeltser, G. / Forrester, T. / Shnitser, P. I. et al. | British Library Conference Proceedings | 2002


    HAPTIC FEEDBACK DEVICE, HAPTIC FEEDBACK METHOD, AND VEHICLE

    ONO AKIRA / ABE HIRONOBU / NISHIIKE AKIHITO | Europäisches Patentamt | 2024

    Freier Zugriff