PURPOSE: Planning target volume (PTV) definition based on Mid-Position (Mid-P) strategy typically integrates breathing motion from tumor positions variances along the conventional axes of the DICOM coordinate system. Tumor motion directionality is thus neglected even though it is one of its stable characteristics in time. We therefore propose the directional MidP approach (MidP dir), which allows motion directionality to be incorporated into PTV margins. A second objective consists in assessing the ability of the proposed method to better take care of respiratory motion uncertainty. METHODS: 11 lung tumors from 10 patients with supra-centimetric motion were included. PTV were generated according to the MidP and MidP dir strategies starting from planning 4D CT. RESULTS: PTVMidP dir volume didn't differ from the PTVMidP volume: 31351 mm3 IC95% [17242-45459] vs. 31003 mm3 IC95% [ 17347-44659], p = 0.477 respectively. PTVMidP dir morphology was different and appeared more oblong along the main motion axis. The relative difference between 3D and 4D doses was on average 1.09%, p = 0.011 and 0.74%, p = 0.032 improved with directional MidP for D99% and D95%. D2% was not significantly different between both approaches. The improvement in dosimetric coverage fluctuated substantially from one lesion to another and was all the more important as motion showed a large amplitude, some obliquity with respect to conventional axes and small hysteresis. CONCLUSIONS: Directional MidP method allows tumor motion to be taken into account more tightly as a geometrical uncertainty without increasing the irradiation volume.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Incorporation of tumor motion directionality in margin recipe: The directional MidP strategy.



    Erscheinungsdatum :

    2021-01-01


    Anmerkungen:

    Physica medica, Vol. 91, p. 43-53 (2021)



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :

    DDC:    629



    Feasibility of a TPS-integrated method to incorporate tumor motion in the margin recipe.

    Dechambre, David / Vander Veken, Loïc / Delor, Antoine et al. | BASE | 2021

    Freier Zugriff

    Technical Report: Bluetooth integration into CLDC/MIDP

    Strang, Thomas | Deutsches Zentrum für Luft- und Raumfahrt (DLR) | 2001

    Freier Zugriff

    A New Directionality Representation

    Gagnon, Eric / Pomerleau, André / Desbiens, André | AIAA | 2003


    Directionality of Helicopter BVI Noise

    Lowson, M. V. | British Library Conference Proceedings | 1995


    RECIPE INDEX

    Online Contents | 2007