This study emphasizes the use of type-2 fuzzy (T2-Fuzzy) to improve the adaptive proportional-integrative-derivative (PID) control in the lower extremities. Several problems were identified from previous studies and those were the slow achievement of the target angle and the presence of oscillation in the achievement of the target blade. The oscillation occurred as the consequence of deploying the early adaptive PID which was not sufficient to overcome the lower extremities nonlinearity. The difference between proposed method of T2-Fuzzy and the others lies in the defuzzification. This research adopts a fast geometric defuzzification that maintains the level of uncertainty T2-Fuzzy in real-time. A functional electrical stimulation (FES) stimulator is proposed to design and to be connected to the computer for processing the T2-Fuzzy. This stimulator stimulates lower extremities of normal subjects each cycle, and the computer record the point of measured achievement of using a goniometer sensors mounted on a knee joint. The results show that the target point of lower extremities is achieved within three initial cycles without oscillations in the achievement of the angle. It is also found that T2-Fuzzy is able to immediately restore the point of achievement when the external parameters of control occur.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Fast Geometric T2-Fuzzy Based Improved Lower Extremities Stimulation Response


    Beteiligte:

    Erscheinungsdatum :

    01.12.2010


    Anmerkungen:

    TELKOMNIKA (Telecommunication Computing Electronics and Control); Vol 8, No 3: December 2010; 207-216 ; 2302-9293 ; 1693-6930 ; 10.12928/telkomnika.v8i3



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch


    Klassifikation :

    DDC:    629


    Lizenzbestimmungen :


    Impact Response and Tolerance of the Lower Extremities

    Mohan, Dinesh / Melvin, John W. / Benson, Joseph B. et al. | SAE Technical Papers | 1975


    Modelling the Lower Extremities Using Multi-body Techniques

    Wismans, J. / Happee, R. / Thunnissen, J. et al. | British Library Conference Proceedings | 1995


    SAFETY RESTRAINT SYSTEM FOR LOWER EXTREMITIES IN AUTOMATED DRIVING

    KERKELING CHRISTOPH / KIRCH JESSICA / THIELMANN JAN et al. | Europäisches Patentamt | 2023

    Freier Zugriff

    Response of the Thor-Lx and Hybrid III Lower Extremities in Frontal Sled Tests

    Shaw, Greg / Crandall, Jeff R. / Rudd, Rodney W. | SAE Technical Papers | 2003


    Comparative evaluation of dummy response with Thor-Lx/HIIIr and Hybrid III lower extremities

    Shaw,G. / Rudd,R.W. / Crandall,J.R. et al. | Kraftfahrwesen | 2002