Two different schemes for Fault Tolerant Control (FTC) based on Adaptive Control, Robust Control and Linear Parameter Varying (LPV) systems are proposed. These schemes include a Model Reference Adaptive Controller for an LPV system (MRAC-LPV) and a Model Reference Adaptive Controller with a H∞ Gain Scheduling Controller for an LPV system (MRAC-H∞GS-LPV). In order to compare the performance of these schemes, a Coupled-Tank system was used as testbed in which two different types of faults (abrupt and gradual) with different magnitudes and different operating points were simulated. Results showed that the use of a Robust Controller in combination with an Adaptive Controller for an LPV system improves the FTC schemes because this controller was Fault Tolerant against sensor fault and had an accommodation threshold for actuator fault magnitudes from 0 to 6. ; Peer Reviewed ; Postprint (published version)


    Zugriff

    Download


    Exportieren, teilen und zitieren



    MRAC + H∞ fault tolerant control for linear parameter varying systems

    Vargas-Martínez, Adriana / Puig, Vicenç / Garza-Castañón, Luis E. et al. | BASE | 2010

    Freier Zugriff


    Optimal Fault Tolerant Control for Linear Time-Varying Singular Systems

    Yao, L. / Zhao, P. / Shi, L. | British Library Online Contents | 2010



    Output Feedback M-MRAC

    Stepanyan, Vahram / Krishnakumar, Kalmanje S. | AIAA | 2013