In order to model the lifetime of the electrochemical cell in an Alkali Metal Thermal to Electric Converter (AMTEC), studies of TiN electrodes on β -alumina solid electrolytes (BASE) have been made to determine the performance parameters over time. The first of a series of experiments in which TiN electrodes are studied in a Vapor Exposure Test Cell is described here, with preliminary results from electrochemical measurements made on the cell. The TiN electrodes tested here perform well, with minimal degradation over 1000 hours of operation at 850 °C.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Lifetime modeling of TiN electrodes for AMTEC cells


    Beteiligte:
    Ryan, Margaret A. (Autor:in) / Williams, Roger M. (Autor:in) / Homer, Margie L. (Autor:in) / Phillips, Wayne M. (Autor:in) / Lara, Liana (Autor:in) / Miller, Jennifer (Autor:in) / El-Genk, Mohamed S. (Herausgeber:in) / Bragg, Mary J. (Herausgeber:in)

    Kongress:

    Space technology and applications international forum - 1998 ; 1998 ; Albuquerque,New Mexico (USA)


    Erschienen in:

    AIP Conference Proceedings ; 420 , 1 ; 1607-1612


    Erscheinungsdatum :

    15.01.1998


    Format / Umfang :

    6 pages





    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Lifetime Modeling of TiN Electrodes for AMTEC Cells

    Ryan, M. A. / Williams, R. M. / Homer, M. L. et al. | British Library Conference Proceedings | 1998



    Advanced Electrodes for AMTEC

    Fiebig, B. / Schuller, M. / Ryan, M. A. et al. | British Library Conference Proceedings | 1999


    Lifetimes of Thin AMTEC Electrodes

    Ryan, M. / Kisor, A. / Williams, R. et al. | British Library Conference Proceedings | 1994


    Advanced electrodes for AMTEC

    Fiebig, Brad / Schuller, Michael / Ryan, Margaret Amy et al. | American Institute of Physics | 1999