A two‐dimensional transient model of a single cell, long Thermionic Fuel Element (TFE) is developed and its predictions are compared with published calculations and experimental data on steady‐state operation of electrically heated, TOPAZ‐II type TFEs. The operation parameters of the TFE, such as axial distributions of the emitter temperature, emission current density, and the electrode voltage are calculated and discussed. Results show that despite the excellent agreement between the model predictions of the axial distribution of the emitter temperature, its predictions of the maximum emission current density was lower by about 17%. This difference is attributed primarily to the J‐V characteristics in the model, which could be different than those of the TOPAZ‐II TFE, hence additional data on the latter is needed. When compared with experimental data, the model predictions of the electric power output are in excellent agreement with the data at thermal power input of 3.5 kW or higher, but within 10% of the data at lower thermal power.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Two‐dimensional steady‐state analysis of an electrically heated thermionic fuel element


    Beteiligte:
    Huimin Xue (Autor:in) / El‐Genk, Mohamed S. (Autor:in) / Paramonov, Dmitry (Autor:in) / El-Genk, Mohamed S. (Herausgeber:in) / Hoover, Mark D. (Herausgeber:in)

    Kongress:

    10th SymposiumùSpace Nuclear Power and Propulsion ; 1993 ; Albuquerque, NM, USA


    Erschienen in:

    AIP Conference Proceedings ; 271 , 3 ; 1661-1672


    Erscheinungsdatum :

    20.01.1993


    Format / Umfang :

    12 pages





    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch




    Transient and Steady-State Analyses of an Electrically Heated Topaz-II Thermionic Fuel Element

    Xue, Huimin / El-Genk, Mohamed S. | SAE Technical Papers | 1992


    Combustion Heated Thermionic Systems

    van Kemenade, H. P. / Veltkamp, W. B. / Sampers, W. F. J. | SAE Technical Papers | 1992


    Thermionic Fuel Element Verification Program

    Samuelson, S. L. / Dahlberg, R. C. / Huffman, F. N. et al. | AIAA | 1987


    Thermionic fuel element verification issues

    Fitzpatrick, G.O. / Huffman, F.N. | Tema Archiv | 1986


    Comparison between Steady-State and Dynamic I-V Measurements from a Single-Cell Thermionic Fuel Element

    Wernsman, B. / University of New Mexico; School of Engineering; Institute for Space and Nuclear Power Studies | British Library Conference Proceedings | 1997