The slip flow and temperature jump boundary conditions are derived for H2 constant flux forced convection in ducts. An exact solution is found for the fully developed equilateral triangular duct. Closed-form formulas for the temperature distribution and the Nusselt number are presented. The exact H2 Nusselt number for the no-slip case is 308/163.
H2 Forced Convection for Slip Flow in an Equilateral Triangular Duct
Journal of Thermophysics and Heat Transfer ; 28 , 1 ; 100-104
2014-01-08
5 pages