This is an experimental study of the synchronization of temperatures in two adjacent cavities that share a common wall, with air as the working fluid. The temperature of each cavity is independently controlled using an on/off thermostat with a finite deadband. Each cavity also has a heater that turns on or off, leading to oscillations in the temperature. The temperature is measured in each cavity. Conduction through the common wall leads to thermal interaction between the cavities. Phase synchronization of the temperature oscillations is observed and, depending on system parameters, there is a phase shift between the oscillations.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Temperature Synchronization of Natural Convection in Adjacent Thermostatically Controlled Cavities


    Beteiligte:
    Sanchez-Lopez, M. (Autor:in) / Chavez-Martinez, R. (Autor:in) / Solorio, F.J. (Autor:in) / Sen, M. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    2020-03-09


    Format / Umfang :

    10 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch




    Thermostatically controlled galley air extraction

    BURD PETER J L | Europäisches Patentamt | 2024

    Freier Zugriff

    THERMOSTATICALLY CONTROLLED GALLEY AIR EXTRACTION

    BURD PETER J L | Europäisches Patentamt | 2023

    Freier Zugriff

    THERMOSTATICALLY CONTROLLED EMERGENCY LUBRICATION SYSTEM

    MUELLER DOUGLAS ROBERT | Europäisches Patentamt | 2021

    Freier Zugriff

    THERMOSTATICALLY CONTROLLED GALLEY AIR EXTRACTION

    BURD PETER J L | Europäisches Patentamt | 2021

    Freier Zugriff

    Thermostatically-controlled multi-mode coolant loops

    PATEL UPENDRA J / MADHAVAN RANGANATHAN | Europäisches Patentamt | 2018

    Freier Zugriff