Comparative tests of the strength and tightness of commercial flush rivets of one type and NACA flush rivers in machine-countersunk and conterpunched joints
Wartime report ; L-297
1945
5 S.
Ill., graph. Darst.
Originally issued as Restricted bulletin 4B18
Langzeitarchivierung durch Technische Informationsbibliothek (TIB) / Leibniz-Informationszentrum Technik und Naturwissenschaften und Universitätsbibliothek
Report
Englisch
Tensile tests of NACA and conventional machine-countersunk flush rivets
Engineering Index Backfile | 1944
|